1 SCOPE
This Standard covers sealless centrifugal pumps of horizontal end suction single stage and centerline dis- charge design. This Standard includes dimensional interchangeability requirements and certain design fea- tures to facilitate installation and maintenance. It is the intent of this Standard that pumps of the same standard dimensional designation from all sources ofsupply shall be interchangeable with respect to mounting dimen- sions, size, and location of suction and discharge noz- zles, input shafts, baseplates, and foundation bolt holes (see Tables 1, 2, 3, and 4).
2 ALTERNATIVE DESIGN
2.1 Extended Design 1 Dimensions for an extended length design alternative are included. The extended length alternative shall con- form to the basic design features ofthis Standard includ- ing those providing interchangeability with respect to mounting dimensions at the casing, size, and location of the suction and discharge nozzles (see column heads withesuffixinTables1 through4fordimensionallimits). Manufacturers, when offering extended length pumps, shall state this fact in their proposal. NOTE: For Tables 1 and 2 the extended length dimension is a maximum value. Any dimension between the standard and maxi- mum extended length is acceptable.
2.2 Alternative Design Alternative designs will be considered, provided they meet the intent of this Standard and cover construction and performance which are equivalent to and otherwise in accordance with this Standard. All deviations from these specifications shall be described in detail by the seller and approved by the purchaser.
3 NOMENCLATURE AND DEFINITIONS All nomenclature and definitions of pump components shall be in accordance with ANSI/HI 5.1 through 5.6. canned motor pump (CMP): a type ofsealless pump which has a common shaft to link the pump and motor in a single sealed unit.
The pumped liquid is circulated throughthemotor, butisisolated fromthemotorcomponents by a corrosion-resistant containment liner. magnetic drive pump (MDP): a type of sealless pump which utilizes an outer ring of permanent magnets or electromagnets to drive an internal rotating assembly consisting of an impeller, shaft, and inner drive member (torque ring or inner magnet ring) through a corrosion- resistant containment shell.
4 DESIGN AND CONSTRUCTION FEATURES
4.1 Pressure and Temperature Limits
4.1.1 Pressure Limits. The design pressure of the pump shall be at least as great as the pressure–tempera- ture rating of ASME B16.5 or ASME B16.42 Class 150 flanges of the material used. Primary pressure-con- taining boundary (and secondary pressure-containing boundary if required) shall be designed to withstand a hydrostatic test at 1.5 times the maximum design pres- sure for the material of construction used (see para. 5.2.1). All primary pressure-containing parts shall also be capable of resisting a vacuum of 14.7 psi (760 mmHG) at 68°F (20°C).
4.1.2 Temperature Limits. Pumps should be available for temperatures up to 500°F (260°C). Jacketing and other modifications may be required to meet the operating temperature.
4.1.3 Statement. Temperature limitations of the liq- uid at the suction flange shall be stated by the pump manufacturer.
NOTE: The application of the pump shall take into consideration the fluid characteristics as supplied by the user. This will require consideration of such characteristics as specific heat and vapor pressure of the liquid which establishes these limits.
4.2 Flanges Suction and discharge nozzles shall be flanged. Flanges shall conform to ASME B16.5 or ASME B16.42 Class 150 standards except that marking requirements are not applicable and the maximum acceptable toler- ance on parallelism of the back of the flange shall be 3 deg, and bolt holes may be tapped where noted in Tables 1 and 3.
Through bolt holes are preferred. When tapped holes are supplied, they shall be noted on the outline drawing. As an option, Class 300 flanges in accordance with ASME B16.5 or ASME B16.42 may be offered subject to manufacturers’ casing pressure–temperature limita- tions. All pumps regardless of flange rating shall con- form to the X and Y dimensions as shown in Tables 1 and 3.